Rev20200513
Fugitive Emissions Thermal
Oxidizer For Destruction Of
Fugitive Emissions & EPA Toxic
Release Inventories Gases (TRI)
Features:
è EPA Compliant for TRI Gases
è NFPA Area Classification
è Data Logger for EPA Compliance
è Active Thermal Combustion Control
Applications:
þ Natural Gas Processing Plants
þ Analyzer Measurement Shelters
þ Tank Farm
þ Marine Gas Offloading
þ Analyzer Vent Line Manifolds
Built to NEC and NFPA Standards for Thermal Oxidizers
Thermal Oxidizer
Controller with
optional Z-Purge
Patent pending combustion chamber utilizing the Venturi effect along with a long life heater element
that is not exposed to the combustion chamber to extend the life of the heating element (MTBF est.
3.3 yrs.), while being able to maintaining the minimum combustion temperature requirement of
1400°F [760°C] for the destruction of Fugitive Emissions &TRI gases at a 99% destructive efficiency.
The Emission Rx™ Thermal Oxidizer will report the combustion temperature to comply with the
regulatory requirements for a minimum combustion temperature to maintain at the 99% combustion
efficiency needed to be in compliance. A data logger is used for governmental compliance reporting.
Thermocouple for active
control of heating element
and government compliance
for minimum destructive
temperature requirements
Ceramic combustion chamber
Embedded “non-wetted”
heating element
Flame and Spark Arrestor
Controller and memory unit for
EPA, TCEQ and AQMD; TITLE V
reporting
Optional Area Classified Pump Not
Shown. Needed for combustion air.
Combustion Systems Inc.
5701 West Minnesota Street
Indianapolis, IN 46241
P 317-390-1100
F 317-390-1111
Website: www.combustionsystemsinc.com
Distributed by:
THERMODYNAMIC LOAD
Base rated for 0 – 15,000 BTU/hr
Optional load ranges up to 100,000 BTU/hr or more
FLOW RATE
7 LPM for Methane [15,000 BTU/hr]
2.8 LPM for Propane [15,000 BTU/hr]
Base rating flow rate for hydrocarbons is based on BTU/hr
thermodynamic load contact for your specific calculation
BACK PRESSURE
<3.0 in.W.C @ 1.9 LPM [4CFH]
<6.0 in.W.C @ full capacity flow rate from source
WETTED MATERIALS
Stainless Steel
Refractory Ceramic
NACE compliance optional sleeve insert - minimal derating
CONNECTION
Gas Inlet: ¾”(in.) NPT
AREA CLASSIFICATION
Thermal Oxidizer has NFPA 86 rating
Designed for: Class 1, Division 2, Groups B, C and D, Built to NEC
and NFPA Standards for Thermal Oxidizers
Electrical Panel Z-Purged option for Class 1, Division 2, Groups B, C
and D (NEC classification without Z-Purge)
Exterior Surface temperature rating T4 135°C [275°F]
Optional Intertek Approval for Thermal Oxidizer and Control Panel:
Class 1, Division 2, Groups B, C and D (Z-Purge Option Needed)
Optional Pump has CSA, FM for Class 1, Division 2, Groups B, C and
D
UTILITY REQUIREMENTS
POWER: 110Vac @ 15.6Amps for Thermal Oxidizer, 110Vac @
4.5Amps for optional Pump
AIR: Instrument Air for optional Z-Purge Panel 20 psig (1.4 Bar)
minimum, water and oil-free, - 40°F (- 40°C) dew point, particles <5µ,
ISA grade and hydrocarbon free
NOTE: With pump option, purge panel is using pump for supply.
CONTROLLER
LCD Display Interface
Data Logger; data collection for EPA, TECQ and AQMD; TITLE V
Reporting
Optional web portal (cloud) data collection
TEMPERATURE
-10 TO +60°C (Controller)
OUTPUTS
RS-485 Modbus
WARRANTY
12-month limited warranty against defects in materials and
workmanship as delivered to original purchaser.
WEIGHTS & DIMENSIONS
up to 15 K Btu/hr
O.D 13 " Diameter Control Panel wt. 30 lbs
O.D. w/Heat Sheild 17 " Diameter Air Source By others Yes
TO Unit Height 40.0 " Height Manifold wt. 2 lbs
OAH 48.0 " Height
Wt 105 lbs
Heat sheild 18 lbs C.P. = Control Panel T.O. = Thermal Oxidizer
15K to 40 K Btu/hr O.D 14.75 " Di ameter Control Panel wt. 30lbs
O.D. w/Heat Sheild 19 " Diameter Air Source By others Yes
TO Unit Height 40.0 " Height Manifold wt. 2 lbs
OAH 50.1 " Height
Wt 200 lbs
Heat sheild 30 lbs C.P. = Control Panel T.O. = Thermal Oxidizer
40K to 80 K Btu/hr Details
O.D 15.5 " Di ameter Control Panel wt. 40 lbs
O.D. w/Heat Sheild 20 " Diameter Air Source By others Yes
TO Unit Height 55 " Hei ght Mani fol d wt. 2 lbs
OAH 66.8 " Height
Wt 300 lbs
Heat sheild 45 lbs C.P. = Control Panel T.O. = Thermal Oxidizer
Dimensions
O.D 17 " Diameter Control Panel wt. 40 lbs
O.D. w/Heat Sheild 22 " Diameter Air Source By others Yes
TO Unit Height 70 " Hei ght Mani fol d wt. 2 lbs
OAH 80.16 " Height
Wt 400 lbs
Heat sheild 65 lbs C.P. = Control Panel T.O. = Thermal Oxidizer
Max distance between
C.P and T.O
100'
Dimensions
Max distance between
C.P and T.O
Details
50'
100'
Max distance between
C.P and T.O
Dimensions